For automatic draining of compressor receiver tanks. Also can be used to drain
Tsunami™ Water separators and filters. Uses 110V standard plug.
- 0.5 to 10 sec. adjustable drain open timing
- 30 sec. to 45 min. adjustable between cycles
- Includes TEST button for manual draining.
- Easy installation
- 1/4 Turn shut-off for maintenance. Complete with 1/2"NPT strainer inlet
- Good for up to 200 HP compressors
- Discharge up to 25 gallons/hour
- 1/2" NPT inlet port / 1/4" NPT drain port
- 4" long x 3.5" wide
For those looking for the most economical method of purging condensation from your receiver tank Suburban offers a timed drain valve with ball valve strainer.
This unit can be installed directly to your compressors receiver tank for programmed release of water and contaminants from the bottom of the tank.
This unit can also be used at the lowest points of air drops around your shop to keep airlines clean.

For those looking for a drain valve with zero-air-loss Suburban also offers the MoistureMinder series of piston drain valves.
The MoistureMinder is powered by a pilot air signal from the head of the compressor and does not require electricity.

if you're looking for more protection at the point-of-use for air tools, may we suggest using this product in conjunction with the Tsunami water separator.
The Tsunami installs just before your air tools to remove that last bit of moisture, thereby ensuring the life of your tools.

INSTALLATION:

When installing the electronic drain valves make sure the power is turned off and air system is drained (zero pressure)
- Verify flow direction, has stamped on valve body
- Valve can be mounted in any position
- Install a condensate drain on the outlet side of drain valve for proper collection and drainage of condensate
- If tubing is used for drain, beware of "whipping" when valve is open
- Removed contact block from connector and attach wires as shown in Contact Block Detail

 |
| Timer Specifications: |
|
| Interval time (T2) |
.5 to 45 minutes |
|
| Discharge time (T1) |
.5 to 10 seconds |
|
| Supply voltage |
24v-240v 50/60Hz (+/-10%) |
|
| Current Consumption |
4mA Max. |
|
| Operating temperature |
-10°C to +50°C |
|
| Environmental protection |
NEMA 4 |
|
| Case Material |
ABS plastic FR grade |
|
| Connection |
DIN 43650A ISO 4400/6952 |
|
|
 |

 |
| Valve Specifications: |
|
| Type |
2-way direction acting valve |
|
| In-Out ports |
1/4", 3/8", 1/2" NPT female |
|
| Max. working pressure |
230 PSI |
|
| Operating Temperature |
2°C to 55°C ambient |
|
| Media Temperature |
90°C Max. |
|
| Valve Body |
Forged Brass |
|
| Orifice |
.157" |
|
| Insulation |
Thermal group F |
|
| Environmental protection |
IP65/NEMA 4 |
|
| Supply voltage |
115v to 240v (see coil) |
|
| Voltage tolerance |
+/- 10% |
|
| Mounting |
Any position |
|
|
 |


Timer Setting:

Set INTERVAL time (T1) using right adjusting knob
set DISCHARGE time (T2) using left adjusting knob

Set T1 to 2 seconds and T2 to 20 minutes. (adjust as necessary)

The electronic drain valve is maintenance free. however, we recommend replacing wearing parts every two years.
It is also recommended that the drain be tested every time the compressed air system is checked.
This can be done by pressing the TEST membrane button on the timer face.



|